Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Language
Year range
1.
Braz. J. Pharm. Sci. (Online) ; 53(3): e00041, 2017. tab, graf
Article in English | LILACS | ID: biblio-889383

ABSTRACT

ABSTRACT A stability indicating HPLC method to determine diltiazem hydrochloride (DTZ) in tablets and compounded capsules was developed and validated according to Brazilian and the International Conference on Harmonization (ICH) guidelines. The separation was carried out on a Purospher Star® C18 (150 x 4.6 mm i.d., 5 µm particle size, Merck Millipore) analytical column. The mobile phase consisted of a 0.05% (v/v) trifluoroacetic acid aqueous solution and a 0.05% trifluoroacetic acid methanolic solution (44:56, v/v). The flow rate was 1.0 mL.min-1 with a run time of 14 minutes. The detection of DTZ and degradation products (DP) was performed at 240 nm, using a diode array detector. The method proved to be linear, precise, accurate, selective, and robust, and was adequate for stability studies and routine quality control analyses of DTZ in tablets and compounded capsules.


Subject(s)
Diltiazem/therapeutic use , Chromatography, High Pressure Liquid/methods , Validation Study , Tablets/pharmacology , Capsules/pharmacology
2.
Braz. j. pharm. sci ; 49(4): 837-843, Oct.-Dec. 2013. ilus, tab
Article in English | LILACS | ID: lil-704116

ABSTRACT

The present study developed and validated an HPLC method for the simultaneous determination of artesunate (AS) and mefloquine hydrochloride (MQ) in fixed-dose combination tablets, according to ICH guidelines. The chromatographic separation was carried out on an XBridge C18 (250 x 4.6 mm i.d., 5 µm particle size, Waters) analytical column. The mobile phase included a 0.05 M monobasic potassium phosphate buffer (pH adjusted to 3.0 with phosphoric acid) and acetonitrile (50 + 50, v/v). The flow rate was 1.0 mL/min, and the run time was 13 minutes. A dual-wavelength approach was employed: AS detection was performed at 210 nm and MQ was detected at 283 nm, using a diode array detector. Stability of sample solutions was evaluated for 8 hours after preparation, during which time the solutions remained stable. Youden's test was employed to evaluate robustness. The method proved to be linear (r²>0.99), precise (RSD<2.0%), accurate, selective, and robust, proving to be appropriate for routine drug quality control analysis.


Um método por cromatografia a líquido de alta eficiência para a determinação simultânea de artesunato (AS) e cloridrato de mefloquina (MQ) em comprimidos em dose fixa combinada foi desenvolvido e validado, de acordo com as normas do ICH. A separação cromatográfica foi realizada com uma coluna analítica XBridge C18 (250 x 4,6 mm d.i., partículas de 5 µm, Waters). A fase móvel foi constituída de tampão fosfato monobásico de potássio 0,05 M (pH ajustado para 3,0 com ácido fosfórico) e acetonitrila (50 + 50, v/v). O fluxo da fase móvel foi de 1,0 mL/min e o tempo de corrida foi de 13 minutos. Utilizaram-se dois comprimentos de onda: a detecção do AS foi realizada em 210 nm e a de MQ foi realizada em 283 nm, utilizando-se um detector de arranjo de diodos. A estabilidade das soluções padrão e amostra foi avaliada por 8 horas após sua preparação e as soluções permaneceram estáveis nesse período. O teste de Youden foi empregado para a avaliação da robustez do método. O método se mostrou linear (r²>0,99), preciso (DPR<2,0%), exato, seletivo e robusto, sendo adequado para análises rotineiras de controle de qualidade dos medicamentos.


Subject(s)
Tablets/analysis , Mefloquine/analysis , Chromatography, High Pressure Liquid/methods , Pharmaceutical Preparations/analysis
3.
Rev. Soc. Bras. Med. Trop ; 44(5): 582-586, Sept.-Oct. 2011.
Article in English | LILACS | ID: lil-602900

ABSTRACT

INTRODUCTION: The emergence of drug resistance is one of the main problems concerning malaria treatment. The use of counterfeit and/or substandard antimalarial drugs can contribute to the development of parasite resistance. Thus, the aim of this study was to evaluate the quality of antimalarial drugs distributed in Brazil. METHODS: Samples containing chloroquine phosphate, mefloquine hydrochloride, primaquine phosphate, and quinine sulfate tablets were delivered to the Rio de Janeiro central storeroom (CENADI), state storerooms (SS), and Basic Health Units (BHUs) in the north region of Brazil - a total of 10 sample sets. After 5 months of storage, the samples were collected, and in vitro quality control analyses according to official and published methods were performed. RESULTS: Inadequate drug storage conditions were found in two SS and in all BHUs evaluated. There were no quality deviations found in the chloroquine samples. The quinine samples exhibited weight variation above the allowed limits. The primaquine samples were found to have packaging deficiency. The release of mefloquine in samples from some regions showed a statistically significant difference when compared with the CENADI samples. CONCLUSIONS: It is important to periodically evaluate the quality and storage conditions of essential drugs. The quality deviations found with the primaquine and quinine samples are not related to storage conditions and must be addressed urgently. The decreased mefloquine release from tablets is related to formulation problems or influenced by inadequate storage conditions, prompting further investigation. Even with the mentioned problems, the samples would probably not contribute to resistant parasite selection.


INTRODUÇÃO: O aparecimento de resistência aos medicamentos é um dos maiores problemas do tratamento da malária. O uso de medicamentos falsos e/ou de má qualidade pode contribuir para o desenvolvimento de resistência no parasita. Este estudo tem por objetivo avaliar a qualidade dos medicamentos antimaláricos distribuídos no Brasil. MÉTODOS: Amostras contendo comprimidos de difosfato de cloroquina, cloridrato de mefloquina, difosfato de primaquina e sulfato de quinina foram enviadas ao almoxarifado central na Cidade do Rio de Janeiro (CENADI), almoxarifados estaduais (SS) e Unidades Básicas de Saúde (UBS) nos estados da região norte do Brasil, totalizando dez amostras. Após cinco meses de armazenamento, as amostras foram coletadas e analisadas segundo métodos oficiais e da literatura. RESULTADOS: Foram encontradas condições inadequadas de armazenamento de medicamentos em duas SS e em todas as UBS avaliadas. Não foram encontrados problemas de qualidade com as amostras de cloroquina. As amostras de quinina apresentaram variação de peso acima dos limites permitidos. Amostras de primaquina foram encontradas com problemas na embalagem. A cedência de mefloquina de comprimidos, em algumas regiões, apresentou diferença estatisticamente significativa quando comparada com a amostra do CENADI. CONCLUSÕES: É importante avaliar, periodicamente, a qualidade e as condições de armazenamento de medicamentos essenciais. Desvios de qualidade encontrados com as amostras de primaquina e quinina não estão relacionados às condições de armazenamento e devem ser corrigidos urgentemente. O decréscimo na cedência de mefloquina dos comprimidos está relacionado com a formulação ou foi influenciada por condições de armazenamento inadequadas, necessitando de uma investigação posterior. Apesar dos problemas mencionados, as amostras provavelmente não contribuiriam para a seleção de parasitas resistentes.


Subject(s)
Humans , Antimalarials/standards , Drug Storage/standards , Drugs, Essential/standards , Brazil , Chromatography, High Pressure Liquid , Chloroquine/standards , Mefloquine/standards , Primaquine/standards , Quality Control , Quinine/standards
SELECTION OF CITATIONS
SEARCH DETAIL